{"product_id":"sdc-lr100jak-quiet-duo-latch-retraction-dogging-kit-for-36-jackson-2000-series-exit-devices","title":"SDC LR100JAK Quiet Duo Latch Retraction \/ Dogging Kit, for 36\" Jackson 2000 Series Exit Devices","description":"\u003ch2\u003eSDC LR100JAK Quiet Duo Latch Retraction \/ Dogging Kit, for 36\" Jackson 2000 Series Exit Devices\u003c\/h2\u003e\u003cp\u003eThe SDC LR100JAK is a QuietDuo LR100 series retrofit kit for Jackson exit devices, listed by SDC for the Jackson 2095 rim and 2085 CVR models. It converts a mechanical panic or fire rated device to motorized electric latch retraction and dogging, with the whole kit housed inside the rail behind the access cover. When energized, the motor pulls the latch back and draws the pushpad into the dogged (depressed) position, so the door can operate in momentary or sustained push and pull mode. The exit device always provides uninhibited egress, and no door sequencer is required for a pair of manual doors with a suitable power supply.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eJackson 2095 rim and 2085 CVR compatible.\u003c\/li\u003e\n\u003cli\u003eAdds electric access control and dogging to a mechanical exit device.\u003c\/li\u003e\n\u003cli\u003eSimultaneous latch retraction, dogging and pushpad depression.\u003c\/li\u003e\n\u003cli\u003eWhole kit housed inside the rail behind the access cover.\u003c\/li\u003e\n\u003cli\u003eRetrofit installation without removing the device from the door.\u003c\/li\u003e\n\u003cli\u003eMotorized mechanism with low current draw: 1.5 amp inrush, 200 mA continuous.\u003c\/li\u003e\n\u003cli\u003eFor high traffic use and low energy operators.\u003c\/li\u003e\n\u003cli\u003ePanic and fire rated device compatible.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFunctional Details\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHow the LR100 operates on the exit device, in SDC's words:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eWhen energized the motor retracts the exit device latch and pulls the pushpad into the dogged (depressed) position enabling momentary or sustained push and pull operation of the door.\u003c\/li\u003e\n\u003cli\u003eThe latch retraction mechanism may be activated by an access control, remote control device or building automation system.\u003c\/li\u003e\n\u003cli\u003eNo door sequencer required for a pair of manual doors when connected to a suitable power supply.\u003c\/li\u003e\n\u003cli\u003eThe exit device always provides uninhibited egress.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eProduct Specifications\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSDC (Security Door Controls)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eLR100JAK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eQuietDuo LR100 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRetrofit motorized electric latch retraction kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExit Device Brand\u003c\/td\u003e\n\u003ctd\u003eJackson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Exit Devices\u003c\/td\u003e\n\u003ctd\u003eRim: 2095, CVR: 2085\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eField install; retrofits without removing the device from the door (factory install also offered by SDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 305 Panic Hardware, UL 10C Positive Pressure Fire Tests, ULC-S104 Standard Method for Fire Tests of Door Assemblies, ANSI\/BHMA A156.3 Grade 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended SDC Power Supply\u003c\/td\u003e\n\u003ctd\u003e602RF for a single door; 602RFUR-1 or 634RF for a simultaneous pair of doors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelated Products (sold separately)\u003c\/td\u003e\n\u003ctd\u003eSDC 602RF power supply (602RFUR-1 or 634RF for a simultaneous pair)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRetrofit ELR Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eOne unit completely housed within the rail of the device behind the access cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e24 VDC ± 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw\u003c\/td\u003e\n\u003ctd\u003e1.5 Amp inrush, 200 mA continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLatch Retraction\u003c\/td\u003e\n\u003ctd\u003eMotorized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThird-Party Power Supply\u003c\/td\u003e\n\u003ctd\u003eLinear, regulated and filtered supply with a minimum rating of 2 amp per LR100 kit recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SDC Commercial Door Hardware","offers":[{"title":"Default Title","offer_id":48542841045198,"sku":"LR100JAK","price":676.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0562\/3493\/4478\/files\/SEC400LR100JAK.png?v=1794344293","url":"https:\/\/qualitydoor.com\/products\/sdc-lr100jak-quiet-duo-latch-retraction-dogging-kit-for-36-jackson-2000-series-exit-devices","provider":"QualityDoor.com","version":"1.0","type":"link"}