NGP GAP90DKB-84 Inch Fire Door Head-Jamb Gap Solutions, Components Includes 9945, 9400B, 5075B, 90-Minute Rated, Restricts The Passage Of Smoke, Non-Handed, Dark Bronze Aluminum


The NGP GAP90DKB-84 is a UL-certified fire door head and jamb solution designed to correct excessive clearances on 60- and 90-minute fire doors with gaps up to 3/8", and 20- to 45-minute doors with gaps up to 9/16". This 84-inch dark bronze aluminum kit includes high-performance components like the 9945 intumescent seal, 9400B housing, and 5075B silicone bulb to ensure a smoke-tight seal that complies with NFPA 80, IBC, and UL10C positive pressure standards. Engineered for commercial hollow metal and wood fire doors with frame stops under 1-3/8" wide, this non-handed solution provides a cost-effective way to bring non-compliant fire doors back into safety code without the need for total door replacement.

Features

  • UL Certified Solution for 60- and 90-Minute Fire Doors with Excessive Clearance Between Door and Frame Over 1/8", up to 3/8".
  • UL Certified Solution for 20- and 45-Minute Fire Doors with Excessive Clearance Between Door and Frame Over 1/8", up to 9/16".
  • Restricts the Passage of Smoke
  • Non-Handed
  • Designed for Use Where Door Frame Stop is Less Than 1-3/8" Wide
  • An NGP Strike Shim (9275 or 9225) may also be Required for Proper Latchbolt Engagement
  • POSITIVE PRESSURE – CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal and Wood fire doors rated up to 90 minute with excessive door and frame clearances, measuring up to 3/8"; and rated up to 45 minutes with excessive clearances up to 9/16"
  • CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal and Wood fire doors rated up to 90 minute with excessive door and frame clearances, measuring up to 3/8"; and rated up to 45 minutes with excessive clearances up to 9/16".