Sargent LC-12-56-8876-F-ETL-24V Electrified Fire Rated Rim Exit Device, Fail Secure Power Off Locks Lever, Key Retracts Latch, Electric Latch Retraction, For 33-36" Width Door, Less Cylinder, Less Dogging
The Sargent LC-12-56-8876-F-ETL-24V is a fire rated rim exit device built for high-traffic openings that require electrified access control. This device features electric latch retraction (ETL) powered at 24V, allowing the latch to be pulled back remotely for momentary or sustained access while maintaining a fail secure condition when power is removed. Designed for 33-36" door widths, it ships less cylinder and less dogging, giving installers flexibility to match existing keying systems. As a fire rated unit, it provides positive latching for life safety and code compliance, making it a dependable choice for commercial and institutional entrances.
Features
- Fire rated rim exit device suitable for labeled fire door assemblies.
- Electric latch retraction (ETL) operates on 24V for remote latch control.
- Fail secure operation keeps the device locked when power is lost.
- Sized for 33-36 inch door widths.
- Supplied less cylinder to accommodate your preferred keying.
- Less dogging, as required for fire rated applications.
- Key retracts the latch for authorized mechanical access.
Functional Details
The electric latch retraction function uses a solenoid or motor to pull the latch back electrically, allowing free passage without mechanical actuation of the pushbar. When power is removed in this fail secure configuration, outside access is locked while egress from the inside always remains available via the pushbar. Keyed access from the outside retracts the latch mechanically.
- Fail Secure: Power off locks lever/no outside access.
- Key retracts latch for outside access.
- Electric latch retraction for remote operation.
Included Components
The device includes the 8876 fire rated rim exit chassis with integrated electric latch retraction hardware and mounting components. A cylinder is not included and must be ordered separately.
| Manufacturer | Sargent |
| SKU | LC-12-56-8876-F-ETL-24V |
| Grade | Grade 1 |
| Origin | USA |
| Unit of Measure | Each |
| UL Listing Type | Fire Rated Exit Device |
| ANSI Number | ANSI/BHMA A156.3 |
| BAA Qualified | Yes |
| Device Type | Rim Exit Device |
| Function | Fail Secure, Electric Latch Retraction |
| Cylinder | Less Cylinder |
| Dogging | Less Dogging (Fire Rated) |
| Limited Warranty | Yes |
| Voltage | 24V DC |
| Door Width Range | 33 - 36 inches |
| Series | 8800 Series |
| Mounting | Rim |
| Latch Type | Deadlatching, Electric Retraction |
| Electrical Function | ETL - Electric Latch Retraction |
| Inrush Current (24V) | 16 A |
| Holding Current (24V) | 0.33 A |
| Fire Rating | 3 Hour (Labeled) |
| Handing | Non-handed |
| Fail Mode | Fail Secure |