Buy Complete Door Hardware Set
- Description
- Product Specifications
- Technical Specifications
- Document Center
- Handing Chart
Sargent RX-LC-8270-12V-LNMI Electrified Fail Safe Mortise Lock, LN Rose, MI Lever, 12VDC, Request to Exit Switch, Less Cylinder, Grade 1, Field Reversible
The Sargent RX-LC-8270-12V-LNMI is an electrified fail safe mortise lock from the 8200 Series with request-to-exit monitoring. With 12VDC applied, the outside lever is locked; when power is removed, it unlocks. From the inside, the lever always retracts the latchbolt; from the outside, a key retracts the latchbolt without electronic activation. Two switches inside the lockbody track inside and outside lever rotation for access control signaling. The lock is supplied less cylinder and comes with an LN rose and an MI lever. The 12 gauge wrought steel case is closed on all sides, and handing can be changed in the field without opening the case.
Features
- Fail safe 70 function: power on locks the outside lever, power off unlocks it.
- The inside lever retracts the latchbolt at all times.
- Key outside retracts the latchbolt for mechanical override without electronic activation.
- Request-to-exit (RX) switches track inside and outside lever rotation separately.
- LN rose with MI lever from the Sargent Studio Collection Aventura Series, through-bolted for proper alignment.
- The same Studio Collection design is offered on Sargent 80 Series exit devices and other Sargent locks, so trim can match across a facility.
- Cylinder not included; the lock takes a standard size #41 (1-1/8") mortise cylinder.
- One-piece stainless steel anti-friction latchbolt with 3/4" throw and a stainless steel auxiliary deadlatch.
- Lock case is 12 gauge wrought steel and fully enclosed on all sides.
- Operates from 12-24VDC regulated with a .015 Amp continuous actuator draw (EcoFlex design).
- Field reversible handing with no parts to remove and no need to open the case.
- Lever design meets ADA requirements under national codes.
- Listed by UL and cUL for fire doors rated up to 3 hours.
Functional Details
Under the 70 function, the outside lever is controlled electronically: applying power locks it and removing power unlocks it. The inside lever always retracts the latchbolt, and the outside key retracts the latchbolt for mechanical override.
- 70 function — Power ON, locks outside lever
- Specify voltage: 12VDC or 24VDC (operates from 12-24VDC)
- Key outside retracts latchbolt
- Lever outside retracts latchbolt, except when locked
- Lever outside can only be locked electronically
- Lever inside always retracts latchbolt
- Auxiliary deadlatch
| Manufacturer | Sargent (ASSA ABLOY) |
| SKU | RX-LC-8270-12V-LNMI |
| Series | 8200 Series Mortise Lock |
| Function | 70 Electrified, Fail Safe |
| Monitoring | RX Request-to-Exit Switch |
| Trim | LN Rose, MI Lever |
| Lever Collection | Studio Collection, Aventura Series |
| Cylinder | Less Cylinder |
| Grade | Grade 1 |
| ANSI Number | ANSI/BHMA A156.13, Series 1000 |
| UL Listing Type | UL and cUL listed, fire doors up to 3 hours (A label) |
| Accessibility | Meets ANSI A117.1 |
| Handing | Field reversible |
| Limited Warranty | 2 years (electrified locks) |
| Voltage | 12VDC (operates from 12-24VDC regulated) |
| Actuator Current Draw | .015 Amp continuous |
| Power Supply Sizing | Maximum 2 locks per 1 Amp power supply (1/2 Amp peak current draw) |
| Operating Temperature | -31°F to 151°F (-35°C to 66°C) |
| Monitoring Switches | Two SPDT (type C) switches, inside and outside lever rotation |
| Cable Run | Over 500 ft with minimum 22 AWG wire |
| Backset | 2-3/4" (70mm) |
| Door Thickness | 1-3/4" (44mm) standard |
| Minimum Stile | 4-3/4" (121mm) for electrical function locks |
| Armored Front | 8" x 1-1/4" (203mm x 31mm), adjustable flat to 1/8" in 2" bevel |
| Latchbolt | 3/4" (19mm) throw, one-piece stainless steel |
| Lock Case | 12 gauge wrought steel, 7/64" (.109") thick |