Buy Complete Door Hardware Set
- Description
- Product Specifications
- Technical Specifications
- Document Center
- Handing Chart
Sargent RX-LC-8271-12V-OL Electrified Fail Secure Mortise Lock, O Rose, L Lever, 12VDC, Request to Exit Switch, Less Cylinder, Grade 1, Field Reversible
The Sargent RX-LC-8271-12V-OL combines the 8200 Series mortise lockbody with the 71 fail secure function and RX request-to-exit monitoring. Applying 12VDC unlocks the outside lever, and removing power locks it again. A key outside retracts the latchbolt at any time, while the inside lever always retracts it. The RX option adds two internal switches that report inside and outside lever rotation to an access control system. Trim is an O rose with an L lever, and the lock ships less cylinder. The EcoFlex design runs from 12-24VDC regulated with a .015 Amp continuous actuator draw.
Features
- Outside lever is unlocked electronically while powered and stays locked on power loss (71 function, fail secure).
- RX request-to-exit option uses two internal switches to monitor inside and outside lever rotation independently.
- Outside key override retracts the latchbolt without electronic activation.
- Latchbolt is always retracted by the inside lever.
- Supplied less cylinder; the 8200 Series uses a size #41 (1-1/8") mortise cylinder, ordered separately.
- EcoFlex electromechanical design operates from 12-24VDC regulated with a .015 Amp continuous actuator draw.
- Closed-on-all-sides case made from heavy duty 12 gauge wrought steel.
- 3/4" throw one-piece stainless steel anti-friction latchbolt, paired with a stainless steel auxiliary deadlatch.
- O rose with standard L lever, through-bolted for proper alignment.
- Complies with the California State Reference Code: the lever returns to within 1/2" (13mm) of the door face.
- Handing changes in the field without removing parts or opening the lock case.
- Fire rated: UL and cUL listed for doors rated up to 3 hours.
- ADA compliant levers for national codes.
Functional Details
In fail secure operation, a power failure leaves the outside lever locked. While power is applied the outside lever is free to operate, a key from the outside still retracts the latchbolt, and the inside lever retracts it at all times.
- 71 function — Power ON, unlocks outside lever
- Specify voltage: 12VDC or 24VDC (operates from 12-24VDC)
- Key outside retracts latchbolt
- Lever outside retracts latchbolt, except when locked
- Lever outside can only be locked electronically
- Lever inside always retracts latchbolt
- Auxiliary deadlatch
| Manufacturer | Sargent (ASSA ABLOY) |
| SKU | RX-LC-8271-12V-OL |
| Series | 8200 Series Mortise Lock |
| Function | 71 Electrified, Fail Secure |
| Monitoring | RX Request-to-Exit Switch |
| Trim | O Rose, L Lever |
| Cylinder | Less Cylinder |
| Grade | Grade 1 |
| ANSI Number | ANSI/BHMA A156.13, Series 1000 |
| UL Listing Type | UL and cUL listed, fire doors up to 3 hours (A label) |
| Accessibility | Meets ANSI A117.1 |
| Handing | Field reversible |
| Limited Warranty | 2 years (electrified locks) |
| Voltage | 12VDC (operates from 12-24VDC regulated) |
| Actuator Current Draw | .015 Amp continuous |
| Power Supply Sizing | Maximum 2 locks per 1 Amp power supply (1/2 Amp peak current draw) |
| Operating Temperature | -31°F to 151°F (-35°C to 66°C) |
| Monitoring Switches | Two SPDT (type C) switches, inside and outside lever rotation |
| Cable Run | Over 500 ft with minimum 22 AWG wire |
| Backset | 2-3/4" (70mm) |
| Door Thickness | 1-3/4" (44mm) standard |
| Minimum Stile | 4-3/4" (121mm) for electrical function locks |
| Armored Front | 8" x 1-1/4" (203mm x 31mm), adjustable flat to 1/8" in 2" bevel |
| Latchbolt | 3/4" (19mm) throw, one-piece stainless steel |
| Lock Case | 12 gauge wrought steel, 7/64" (.109") thick |
| L Lever | 5" (127mm) long, 2-3/8" (60mm) from door face |