Buy Complete Door Hardware Set
- Description
- Product Specifications
- Technical Specifications
- Document Center
- Handing Chart
Sargent RX-LC-8271-12V-OMI Electrified Fail Secure Mortise Lock, O Rose, MI Lever, 12VDC, Request to Exit Switch, Less Cylinder, Grade 1, Field Reversible
The Sargent RX-LC-8271-12V-OMI is an electrified fail secure mortise lock from the 8200 Series with request-to-exit monitoring. Power at 12VDC releases the outside lever, and a loss of power keeps it locked. The RX option adds two internal switches that report inside and outside lever rotation to an access control system. The outside lever can only be locked electronically, and the inside lever always retracts the latchbolt. It is supplied less cylinder, so the cylinder is ordered separately, and it is fitted with an O rose and an MI lever. The EcoFlex design runs from 12-24VDC regulated with a .015 Amp continuous actuator draw.
Features
- Outside lever is unlocked electronically while powered and stays locked on power loss (71 function, fail secure).
- RX request-to-exit option uses two internal switches to monitor inside and outside lever rotation independently.
- Outside key override retracts the latchbolt without electronic activation.
- Latchbolt is always retracted by the inside lever.
- Supplied less cylinder; the 8200 Series uses a size #41 (1-1/8") mortise cylinder, ordered separately.
- EcoFlex electromechanical design operates from 12-24VDC regulated with a .015 Amp continuous actuator draw.
- Closed-on-all-sides case made from heavy duty 12 gauge wrought steel.
- 3/4" throw one-piece stainless steel anti-friction latchbolt, paired with a stainless steel auxiliary deadlatch.
- O rose with MI lever from the Sargent Studio Collection Aventura Series, through-bolted for proper alignment.
- Matching Studio Collection trim is offered on Sargent 80 Series exit devices and other Sargent locks.
- Handing changes in the field without removing parts or opening the lock case.
- Fire rated: UL and cUL listed for doors rated up to 3 hours.
- ADA compliant levers for national codes.
Functional Details
Under the 71 function, the outside lever is controlled electronically: applying power unlocks it and removing power locks it. The inside lever always retracts the latchbolt, and the outside key retracts the latchbolt for mechanical override.
- 71 function — Power ON, unlocks outside lever
- Specify voltage: 12VDC or 24VDC (operates from 12-24VDC)
- Key outside retracts latchbolt
- Lever outside retracts latchbolt, except when locked
- Lever outside can only be locked electronically
- Lever inside always retracts latchbolt
- Auxiliary deadlatch
| Manufacturer | Sargent (ASSA ABLOY) |
| SKU | RX-LC-8271-12V-OMI |
| Series | 8200 Series Mortise Lock |
| Function | 71 Electrified, Fail Secure |
| Monitoring | RX Request-to-Exit Switch |
| Trim | O Rose, MI Lever |
| Lever Collection | Studio Collection, Aventura Series |
| Cylinder | Less Cylinder |
| Grade | Grade 1 |
| ANSI Number | ANSI/BHMA A156.13, Series 1000 |
| UL Listing Type | UL and cUL listed, fire doors up to 3 hours (A label) |
| Accessibility | Meets ANSI A117.1 |
| Handing | Field reversible |
| Limited Warranty | 2 years (electrified locks) |
| Voltage | 12VDC (operates from 12-24VDC regulated) |
| Actuator Current Draw | .015 Amp continuous |
| Power Supply Sizing | Maximum 2 locks per 1 Amp power supply (1/2 Amp peak current draw) |
| Operating Temperature | -31°F to 151°F (-35°C to 66°C) |
| Monitoring Switches | Two SPDT (type C) switches, inside and outside lever rotation |
| Cable Run | Over 500 ft with minimum 22 AWG wire |
| Backset | 2-3/4" (70mm) |
| Door Thickness | 1-3/4" (44mm) standard |
| Minimum Stile | 4-3/4" (121mm) for electrical function locks |
| Armored Front | 8" x 1-1/4" (203mm x 31mm), adjustable flat to 1/8" in 2" bevel |
| Latchbolt | 3/4" (19mm) throw, one-piece stainless steel |
| Lock Case | 12 gauge wrought steel, 7/64" (.109") thick |