Sargent RX-LC-8272-12V-LNND Electrified Fail Safe Double Cylinder Mortise Lock, LN Rose, ND Lever, 12VDC, Request to Exit Switch, Less Cylinder, Grade 1, Field Reversible
The Sargent RX-LC-8272-12V-LNND combines the 8200 Series mortise lockbody with the 72 fail safe function and RX request-to-exit monitoring. Power at 12VDC keeps both levers locked, and a loss of power leaves both sides free to operate. Two switches inside the lockbody track inside and outside lever rotation for access control signaling. The levers cannot be locked separately, and a key on either side retracts the latchbolt. It is supplied less cylinder, so the cylinder is ordered separately, and it is fitted with an LN rose and an ND lever. It is rated Grade 1 under ANSI/BHMA A156.13 and is UL and cUL listed for fire doors rated up to 3 hours.
Features
- Fail safe 72 function: power on locks both levers, power off unlocks them.
- Request-to-exit (RX) switches track inside and outside lever rotation separately.
- A key on either side retracts the latchbolt mechanically, without electronic activation.
- Less cylinder: order a size #41 (1-1/8") mortise cylinder separately.
- Operates from 12-24VDC regulated with a .015 Amp continuous actuator draw (EcoFlex design).
- Closed-on-all-sides case made from heavy duty 12 gauge wrought steel.
- One-piece stainless steel anti-friction latchbolt with 3/4" throw and a stainless steel auxiliary deadlatch.
- LN rose with ND lever from the Sargent Studio Collection Centro Series, through-bolted for proper alignment.
- Lever returns to within 1/2" (13mm) of the door face, complying with the California State Reference Code.
- The same Studio Collection design is offered on Sargent 80 Series exit devices and other Sargent locks, so trim can match across a facility.
- Handing changes in the field without removing parts or opening the lock case.
- Fire rated: UL and cUL listed for doors rated up to 3 hours.
- Lever design meets ADA requirements under national codes.
Functional Details
With the 72 function, power holds both levers locked and a loss of power releases them. The levers cannot be locked separately; electronic control always changes both together, and a key on either side retracts the latchbolt.
- 72 function — Power ON, locks both levers
- Specify voltage: 12VDC or 24VDC (operates from 12-24VDC)
- Key on either side retracts latchbolt
- Lever from either side retracts latchbolt, except when levers are locked
- Both Levers can only be locked & unlocked electronically
- Levers can not be locked separately, only together
- Auxiliary deadlatch
| Manufacturer | Sargent (ASSA ABLOY) |
| SKU | RX-LC-8272-12V-LNND |
| Series | 8200 Series Mortise Lock |
| Function | 72 Electrified, Fail Safe |
| Monitoring | RX Request-to-Exit Switch |
| Trim | LN Rose, ND Lever |
| Lever Collection | Studio Collection, Centro Series |
| Cylinder | Less Cylinder |
| Grade | Grade 1 |
| ANSI Number | ANSI/BHMA A156.13, Series 1000 |
| UL Listing Type | UL and cUL listed, fire doors up to 3 hours (A label) |
| Accessibility | Meets ANSI A117.1 |
| Handing | Field reversible |
| Limited Warranty | 2 years (electrified locks) |
| Voltage | 12VDC (operates from 12-24VDC regulated) |
| Actuator Current Draw | .015 Amp continuous |
| Power Supply Sizing | Maximum 2 locks per 1 Amp power supply (1/2 Amp peak current draw) |
| Operating Temperature | -31°F to 151°F (-35°C to 66°C) |
| Monitoring Switches | Two SPDT (type C) switches, inside and outside lever rotation |
| Cable Run | Over 500 ft with minimum 22 AWG wire |
| Backset | 2-3/4" (70mm) |
| Door Thickness | 1-3/4" (44mm) standard |
| Minimum Stile | 4-3/4" (121mm) for electrical function locks |
| Armored Front | 8" x 1-1/4" (203mm x 31mm), adjustable flat to 1/8" in 2" bevel |
| Latchbolt | 3/4" (19mm) throw, one-piece stainless steel |
| Lock Case | 12 gauge wrought steel, 7/64" (.109") thick |