- Description
- Specifications
- Document Center
Description
Schlage ND82 Institution Lock- Both levers are fixed. Entrance by key in either lever.
Schlage ND82 heavy-duty Institution lever lock for commercial, institutional, and industrial applications. Interior and exterior doors for schools/universities, hospitals/healthcare facilities, offices, retail, and government facilities.
Specifications
ND Mechanical and ND Wired Electrified | ND Wireless Electronic | ||
Chassis | Material | The modular design of zinc and steel components plated for corrosion protection | |
Door thickness | Standard: 1-5/8" to 2-1/8" Optional: 1-3/8" - 6" EE, EO, EI, ED configurations |
Standard - 1-5/8" to 2" | |
Levers | Standard: Nine designs, pressure cast zinc, plated to match product finish specification Optional: Tactile feature - Athens (ATH), Rhodes (RHO), Sparta (SPA), Tubular (TLR), LAT (Latitude), LON (Longitude), BRW (Broadway), BRK (Boardwalk) |
||
Roses | Wrought brass, bronze, or zinc, plated to match product finish specification | Zinc, plated to match product finish specification | |
Finishes | 10 available (605, 606, 612, 613, 619, 622, 625, 626, 626AM, 643e) | 9 available (605, 606, 612, 619, 622, 625, 626, 626AM, 643e)" | |
Latches | Backset | Standard: 2 3⁄4" Optional: 2 3⁄8", 3 3⁄4", 7 3⁄4" |
Standard: 2 3⁄4" Optional: 2 3⁄8" |
Faceplate | Standard : 1 1⁄8" x 2 1⁄4" Optional: 1" x 2 1⁄4" for 2 3⁄8" backset doors |
Standard: 1 1⁄8" x 2 1⁄4" | |
Bolt | Standard : 1⁄2" throw via Oil Impregnated Stainless Steel Optional : 3⁄4" throw anti-friction bolt available for pairs of doors |
||
Strike | Standard: ANSI Curved Lip: 1 1⁄4" x 4 7⁄8" x 1 3⁄16" Optional: T Strike, ANSI strikes with alternative lip lengths, dust box options |
||
Keying | Formats | Standard: 3 Schlage (KIL or FSIC or SFIC) Optional: 10 Non-Schlage including cylinders from Best, Corbin Russwin, Medeco, Sargent and Yale |
|
Access security | Standard: 6-Pin Patented Everest 29 Optional: Open, Restricted, Primus, master keying, construction keying |
||
Warranty | Mechanical | 10 years mechanical, 1 year wired electrified | 1 year wireless electronic |
Certifications | ANSI/BHMA | All ND-Series comply with A156.2 performance requirements for grade 1 cylindrical locks. Wired electrified complies with A156.25 (indoor), wireless electronic complies with A156.25 (indoor/outdoor) requirements for electrified locking devices. | |
ICC | Complies with ICC A117.1 Accessible and Usable Buildings and Facilities | ||
UL/cUL | All locks 3 hour A label single firedoor 4'0" x 10'0"; pair doors 3 hour firedoor 8'0" x 8'0" with 3⁄4" latch option; pair doors 90 minute fire 8'0" x 10'0" with 3⁄4" latch option. | ||
CA Fire Code | All levers with a return to the door of 1 ⁄2" (64 mm) or less comply (Rhodes, Sparta, Tubular, Omega, Longitude and Boardwalk) | ||
FL Building Code | Complies with Florida Building Code (ASTM E330, E1886, E1996) and Miami Dade (TAS 201, 202, 203) requirements for hurricanes | ||
Federal | Meets FF-H-106C Series 161 | — | |
Other | — | UL294, CSA C22.2 No. 205-M1983, FCC Part 15, IC RSS-210, RoHS |
Document Center
>